- Industrial Products
-
Products
- EDM Wire
- Aluminum Alloy Welding Wire
- Nickel Alloy Wire
- Kalmar Parts
- EDM Consumables
German KROHNE OPTIMASS 1400C (S15 S25 S40 S50) Compact Coriolis Mass Flowmeter
The Standard Mass Flowmeter with an Exceptional Price-to-Performance Ratio
When your process demands true mass flow measurement — independent of viscosity, density, conductivity, and flow profile — the KROHNE OPTIMASS 1400C is the smart, cost-effective choice. This German-engineered Coriolis mass flowmeter combines the proven OPTIMASS 1000 twin-tube sensor with the powerful MFC 400 signal converter in a compact (integral) one-piece design, available in the four most versatile sensor sizes: S15, S25, S40, and S50 — covering everything from precise chemical dosing to full-scale process loading.

Why the OPTIMASS 1400C Outperforms Its Price Class
1. Innovative Twin Straight Measuring Tubes
At the core of the OPTIMASS 1400C is KROHNE's twin straight measuring tube design in duplex stainless steel, with an optimized flow divider that keeps pressure loss to an absolute minimum — saving pump energy over the entire service life. The straight-tube geometry makes the meter exceptionally easy to drain and clean: no cavities, no dead legs, fully drainable in vertical installation — a decisive advantage in batching, product changeover, and hygienic duties. The meter is immune to cross-talk, so instruments can be installed in series or parallel without interference.
2. True Multi-Variable Measurement from One Device
The OPTIMASS 1400C measures mass flow, density, and temperature directly, and derives volume flow and solids content/concentration from them. One instrument replaces a flowmeter, a densitometer, and a temperature probe — one process connection, one wiring run, one calibration record. Measurement accuracy is ±0.15% of rate for liquids and ±0.35% for gases, with density accuracy of ±2 kg/m³ (improvable with on-site calibration) — precision that pays for itself in dosing accuracy, yield accounting, and custody-oriented applications.
3. EGM™ Entrained Gas Management — Measurement That Never Stops
Thanks to KROHNE's patented Entrained Gas Management (EGM™) in the MFC 400 converter, the OPTIMASS 1400C keeps measuring accurately even when gas entrainment occurs — from 0% all the way to 100% gas fraction. Where conventional Coriolis meters trip into alarm and freeze their outputs, the 1400C stays in service, protecting your batch, your control loop, and your production schedule.
4. Plug-and-Play Modular Electronics with Redundant Data Storage
The MFC 400 converter features a modular, pluggable electronics core with redundant data storage: if an electronics module ever needs replacement, the new one reads the configuration automatically — no laptop, no re-commissioning, no process interruption. Comprehensive self-diagnostics (including NE 107-compliant status reporting and the EGM gas detection system) continuously verify both device health and process conditions.
5. One Size Range, Every Standard Duty
The four sensor sizes cover the classic process spectrum:
|
Sensor |
Connection |
Liquid flow range (max.) |
Typical duty |
|
S15 |
DN15/DN25, PN40 |
6,500 kg/h |
dosing, additives, pilot lines |
|
S25 |
DN40, PN40 |
27,000 kg/h |
batching, filling, blending |
|
S40 |
DN50, PN40 |
80,000 kg/h |
process lines, mix control |
|
S50 |
DN80 |
higher, on request |
loading, transfer, plant feed |
All sizes are available with standard flanges (EN 1092/ANSI) or hygienic connections for food, beverage, and pharmaceutical service. Process temperatures reach –40 to +130 °C, pressure up to 100 bar, and the pressure-resistant stainless housing is rated IP66/IP67 — ready for wash-down areas and harsh outdoor plants.
Seamless Integration
Standard outputs include 4–20 mA with HART, pulse/frequency, and dual status outputs; fieldbus options extend to PROFIBUS PA, PROFINET, Modbus, FOUNDATION Fieldbus, and EtherNet/IP. Power supply accepts 100–230 VAC or 12–24 VDC. With no straight-run requirements and no special mounting constraints, the meter installs wherever your piping allows — even in retrofit skids with tight layouts.
Typical Applications
- Dosing and filling lines where every gram counts
- Blending and mix control in chemicals, paints, detergents
- Food & beverage and pharma: syrup, milk, flavour dosing with hygienic connections
- Water and wastewater treatment: polymer and chemical dosing
- Pulp & paper, petrochemical, OEM skids
The Bottom Line
The OPTIMASS 1400C delivers flagship Coriolis technology — twin straight tubes, EGM™ gas management, plug-and-play MFC 400 electronics — at a price point that fits standard process budgets. If you have been hesitating to move to mass flow measurement because of cost, this is the meter that removes the barrier.
Contact us today with your medium, flow range, and connection requirements — our technical team will configure the correct S15/S25/S40/S50 version for your application and quote genuine German KROHNE quality at competitive pricing.